Statistics for Texas Basic Waste Water Operations Ch#05 The Collection System

Click here to take the quiz!

General Stats

  • This quiz has been taken 7 times
  • The average score is 31 of 38

Answer Stats

QuestionAnswer% Correct
A ladder must be within ________ feet of anyone in the trench.25
100%
Lift station designs include ________.all of the above
100%
The ________ pump is most commonly used in a lift stationcentrifugal
100%
The ________ valve, usually a swing type, prevents water on the discharge side of the pump from flowing backwards through the pump when it is off.check
100%
The most important benefit of a collection system is comfort and convenience.False
100%
If gasoline or solvent odors are detected in a manhole, the operator should hold their breath while opening.False
100%
When wastewater cannot flow to treatment by ________, a lift station is used.gravity
100%
Wastewater flowing into a collection system should come from ________.homes, businesses, AND industry
100%
Motors used in wastewater are typically three-phase ________ motors.induction
100%
Dry well stations have the ________ and pumps in a dry well separated from the adjacent wet well.motors
100%
A ________ maintenance program keeps emergency repairs to a minimum.preventive
100%
________ are important to lift station operation and maintenance.Records
100%
When chemicals are used in the system, consider worker and public ________.safety
100%
Hydrogen sulfide is very toxic and deadens the sense of ________.smell
100%
Grade (or slope) and flow velocity are important to wastewater pipe installation.True
100%
Safety rules for manholes include checking for gases and sufficient oxygen, wearing a lifeline, and having two workers assisting at the surface.True
100%
The purpose of the collection system is to collect and transport waste to the point of treatment.True
100%
To reduce gases, the TCEQ requires lift stations to have a ________ system.ventilation
100%
If a ladder is used, it must be portable and extend ________ feet above the trench, in addition to being secured.3
80%
OSHA sets standards for shoring, sloping, or trench boxes for trenches ________ feet or deeper.5
80%
Maps should be as built, showing corrections made in the field during ________.construction
80%
Pipe should be laid down so that the bell end is facing downstream or downhill.False
80%
The primary cause of stoppages is roots or ________.grease
80%
Foreign matter in the ________ can cause noisy operation and should be investigated.impeller
80%
Parts of a collection system include wastewater lines, wastewater crossings, inverted siphons, cleanouts, manholes, and lift stations.True
80%
Install wastewater lines no closer to a water line than ________ feet.9
60%
Records include a ________ checklist.daily
60%
Pipe materials used in collection system construction include polyvinyl chloride, clay, concrete, and bituminous fiberboard.False
60%
Common methods to detect liquid depths and control pumps are ________, pneumatic bubblers, electric probes, and ultrasonic sensors.floats
60%
The best design of isolation valve is the ________ valve because it leaves an unrestricted path when fully open.gate
60%
The ________ valve is the most commonly used valve in the collection system.gate
60%
Wastewater cleaning can increase pipe capacity, prevent septic conditions, maintain flow velocity, and ________.reduce stoppages
60%
If a pump loses prime, it will heat up and damage the ________.seal
60%
________ pumps in dry wells collect packing seal leakage as well as cleanup water.Sump
60%
Hydraulic cleaners (jetting units) use ________ under pressure, which is forced through nozzles.water
60%
Excavation spoil must be at least ________ feet from the edge of the trench.2
40%
If the trench is ________ feet or deeper, a means of exit is required.4
40%
For any gravity wastewater, the minimum velocity required to keep solids in suspension is 1ft/sec.False
20%

Score Distribution

Percentile by Number Answered

Percent of People with Each Score

Your Score History

You have not taken this quiz